MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4

VERSION FEATURES:
DIAGNOSTIC MODE:
Troubles Associated with the Surface Area Heaters:
| PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
| NO IGNITION AT GRIDDLE / FT | Improper gas type | Check for gas type and advise owner if improper. May have to convert unit to LP/Natural gas |
| Defective electrode | Ohm electrode with wire. If open replace electrode | |
| No gas | Check gas supply, make sure gas is turned on at shut off valve on manifold and supply source. Check gas pressure with a manometer | |
| Defective DSI board | Perform DSI board troubleshooting procedures located at end of section 6 |